Article Details
Summary
The Bolt S.O.S. menu is the internal menu on the Ingenico iPP350 Bolt terminal. You open it with the device keyboard. It shows the firmware version, date and time, server properties, and Ethernet properties.
Steps
Open and Move Through the Menu
Press F, 7, 6, 7 on the number pad to open the menu. Then use these keys:
- Press F2 to move down.
- Press F3 to move up.
- Press O (green button) to select.
- Press < (yellow button) to clear.
- Press X (red button) to cancel or go back to the main menu.
Check the Firmware Version
- Open the Bolt S.O.S. menu.
- Press O to select Version. The screen shows the firmware version.
- Press X to go back to the main menu.
Set a Static IP Address
A static IP address is optional. Usually the network gives the device an IP address automatically.
- Check that the firmware is version 1.6.1 or higher. If it needs an update, see CardPointe's Contacting Support.
- Press X to return to the main menu.
- Press F2 to move down to Ethernet Properties.
- Press O to select it.
- Press < to switch the setting from DHCP to Static.
- Press O to edit the static IP settings.
- Press F2 to move between the network fields. Press O to enter a new value on the number pad. Press < to erase the last value.
- Press O to save the value. Keep using F2 to move between fields until you enter all the values.
- Press O to save.
- Press O to continue with a terminal reset.
Related Articles
- Ingenico iPP350 Bolt Terminal Topic Outline
- Set Up the Ingenico iPP350 Bolt How-To
- Configure Ingenico iPP350 Bolt Settings Reference
Comments
0 comments
Article is closed for comments.